| Input Voltage & Frequency |
Universal
|
AC 90V~264V 47-63 Hz
|
| Rated Input Power |
(Shown on the label) |
|
| Inrush current (cold) |
Depends on requirement or design |
50 mA Max. |
Output Rating
Voltage
Current / VA
|
Full Load
Various (see tables) +/- 5%
Various (see tables)
|
No Load
105% output voltage Max.
0 mA
|
| Insulation Resistance |
|
500VDC 50MΩ MIN. |
| Dielectric Strength |
Input - Output (UL/CSA version)
|
3.0KV for 1 minute
|
| Operating Environment
|
Temperature
Humidity
|
-10ºC ~ 40ºC
20% - 80%
|
| Storage Environment |
Temperature
Humidity
|
-20ºC ~ 70ºC
20% - 90%
|
| Insulation Grade |
CLASS B |
130ºC |
| Temperature Rise |
|
95 Deg. Max. @ rated load |
| Agency Safety |
89/36/EEC 73/23/EEC CB/CE/EN 60950 / IEC 950
UL-1950, CSA 950
|
| Efficiency |
70% Normally @ rated load |
| Protection |
Over heat protection
Over current/short circuit protection
Over voltage protection
L.P.S. complied
|
| Ripple & Noise (1MHz BW output) |
2% output voltage Max. |
| Line Regulation |
+/- 1% |
| Hold up time |
3 ms |
| Burn in Test |
100% in mass production |