MG Series - AC/AC Adaptors
|
Description: These models are designed from EI-35 to EI-66 core size. It provides US, UK, Europe, Australian and worldwide plug for input and provides a 6ft. lead wire with coax plug for output. These power supplies offer various AC output voltages and currents. Plug-in type or desk mount could be available.
|
|
|
Features:
High efficiency, low heat generation
Full approvals & CE marking
100,000 hours MTBF
Over heat protection or Class 2 inherently limit
Graceful appearance
|
|
Electrical Characteristics
| Input Voltage & Frequency |
UL/CSA
Europe, UK, CE
Australia
Japan T-Mark
|
120VAC 60 Hz
220V ~ 240VAC 50Hz
240VAC 50Hz
100VAC 50/60 Hz
|
| Rated Input Power |
(Shown on the label) |
|
| Exciting Current |
Depends on requirement or design |
150 mA Max. |
Output Rating
Voltage
Current
|
Full Load
Various (see tables) +/- 5%
Various (see tables)
|
No Load
125% output voltage Max.
0 mA
|
| Insulation Resistance |
|
500VDC 100MΩ MIN. |
| Dielectric Strength |
Input - Output (EU version)
Input - Output (UL/CSA version)
|
3.75KV for 1 minute
1.24KV for 1 minute
|
| Operating Environment
|
Temperature
Humidity
|
-10ºC ~ 40ºC
20% - 80%
|
| Storage Environment |
Temperature
Humidity
|
-20ºC ~ 70ºC
20% - 90%
|
| Insulation Grade |
CLASS A, E, B |
Min 105ºC. Max 130ºC |
| Temperature Rise |
|
75 Deg. Max. @ rated load |
| Agency Safety *note 1 |
89/36/EEC 73/23/EEC CB/CE/EN 60950 / IEC 950
UL-1310, CSA 22.2 No.223
Electrical appliance and material control law of Japan
AS/NZS 3260
|
| Efficiency |
70% Normally @ rated load |
| Protection |
Built a 115ºC or 130ºC thermal fuse on the primary winding.
Inherently limited protection or non-inherently limited (fused secondary) |
Mechanical Description:
| Core Size |
From EI-35, 41, 48, 57, 60 to EI-66 |
| Enclosure Type |
Wall mount ( for EI-35, 41, 48, 57) see note 2
Desk mount (for EI-41, 48, 57, 60, 66)
|
Note 1: Agency safety approvals are applicable to standard models, other special requirements shall be re-applied.
Note 2: If model is designed to IEC, EN, BS, Australian standards, the enclosure shall be meet desk mount for EI-57 and above.
|
|